MPS Pressure Steam Sterilizer

This series cabinet pressure steam sterilizer uses saturated steam as sterilization medium, through the way of gravity exhaust steam to exclude cold air, so that the saturated steam can completely penetrate to the surface of the article, using high temperature saturated steam under high pressure to kill all microorganisms and their spores, the sterilization effect is reliable, is the most effective physical sterilization method. It is widely used in pharmaceutical, biological engineering, laboratory and other fields to sterilize fabrics, instruments, rubber, liquid,etc.
MPS Series Pressure Steam Sterilizer
This series cabinet pressure steam sterilizer uses saturated steam as sterilization medium, through the way of gravity exhaust steam to exclude cold air, so that the saturated steam can completely penetrate to the surface of the article, using high temperature saturated steam under high pressure to kill all microorganisms and their spores, the sterilization effect is reliable, is the most effective physical sterilization method. It is widely used in pharmaceutical, biological engineering, laboratory and other fields to sterilize fabrics, instruments, rubber, liquid,etc.
                      
MPS Series Pressure Steam Sterilizer
Using microcomputer control technology, touch screen operation, the whole process (heating, sterilization, exhaust steam, drying) the whole process of automatic program operation.
Touch screen automatically displays operating status, temperature, pressure, time and other parameters as well as fault alarm information.
With fabric, instrument, rubber, liquid, custom 4 sterilization procedures for users to choose.
Built-in high efficiency steam generator, can quickly produce constant pressure steam, do not pollute sterilized goods.
Optional configuration of micro printer, real-time sterilization process and fault alarm information.
When the program cycle ends, there is a buzzer prompt when the fault alarm occurs.

Safety device:
Overtemperature automatic protection device: the system automatically cuts off the power supply when the temperature exceeds the setting.
Door safety interlocking device: electronic door lock is adopted. Only when the door is closed in place, the sterilizer can start the working procedure. If there is pressure in the inner room or the power supply is not connected, the electronic door lock locks the door handle and the door cannot be opened.
Dry burning alarm device: when the water level is lower than the low water level, the heating power will be cut off automatically and alarm information will be displayed.
Overpressure relief valve: when the set pressure is exceeded, the relief valve opens to release the pressure.
Electronic circuit safety device: DC control circuit with overvoltage overload protection, ac main circuit with short circuit protection.
Technical parameters:
Design pressure: 0.3MPa;
Rated working pressure: 0.23MPa
Pressure display accuracy: 0.1kpa
Sterilization temperature: 105 ~ 136
 
Temperature display accuracy 0.1

Maximum temperature: 136 
Temperature uniformity: ≤±0.5
;
Cavity material: SUS304 stainless steel

MPS Series Pressure Steam Sterilizer
Model Chamber Volume
(L)
Dimensions Weight
(Kg)
Power
D×L L×W×X
MPS-45 316*590 45 750*520*500 55 220V,50HZ 3KW
MPS-60 380*500 60 985*600*1450 105 380V,50HZ 4.5KW
MPS-80 380*700 80 985*600*1450 120 380V,50HZ 5.7KW
MPS-135 500*700 135 1000*710*1550 200 380V,50HZ 9.35KW
MPS-185 500*950 185 1250*710*1550 230 380V,50HZ 10.8KW
MPS-300 630*1000 300 1350*950*1750 350 380V,50HZ 12KW











Note:
1. The voltage and motor power about the power supply can be selected by the customer’s specific requirements.
We provide Customized Machines. The above specifications are only for reference and subject to change without prior notice, please confirm with our sales representative when making order.